[2023] All Measure of Prevention of Overheating of a Transformer

    The overheating in a transformer can cause serious damage to their parts, failure, fire or explosion that leads to power outage so, overheating must be prevented for the continue operation of the electrical power system network. All preventive measure of overheating of a transformer has been explained below.
Measure of Prevention of Overheating of a Transformer

1) Proper Load Management

    Proper load management means monitoring the load on the transformer and ensuring that it is operating with its rated  capacity. Load monitoring equipment such as ammeter and power meters is used to measure the load and adjust it as necessary.

    Load sharing between the all three phase of the transformer must be balanced for proper operation of the transformer to reduce the heat production in order to prevent overheating.

2) Proper Cooling and ventilation

    Proper cooling and ventilation means proper flow of air and circulation of insulating oil around the winding, core and through the oil tube of the transformer dissipating the heat and keeping the temperature within the standard safe range either by natural air or installing fans.

3) Temperature Monitoring

    Monitoring the temperature of the transformer help identify when it is operating above the safe standard range by using temperature monitoring equipment like mog (Magnetic oil guage). Cooling system must be connected with the mog or temperature monitoring equipment so that it can start  the cooling system of the transformer when temperature rises above standard safe value.

4) Regular Maintenance

    Regular maintenance means inspection of the transformer main tank or cooling tubes for wear and tear, inspection of insulation, silica-gel breather, cooling systems, bushings, and proper loading. It helps to identify the problems before they can damage the major parts of the transformer and cause serious problem like failure of transformer and power outage.

5) Proper Sizing

    Proper sizing means using transformer of required KVA to serve the consumers. By using transformer of correct size reduces overloading on the transformer as well as prevent overheating.

6) Earthed Neutral

    Neutral on a transformer must be earthed to ensure zero potential by transferring any raised potential to the ground which can damage to other parts of transformer that lead to overheating.

Conclusion

    Hope, you have understand about all the measure of prevention of overheating of a transformer. Make sure to your opinion and suggestion about this post in the comment section below.